Oct 14, 2022 Leave a message

Tile Roof Construction Practices Of Buildings

Abstract: 1) All roof tiles with qualified quality should be regarded as a waterproof. When the material, thickness and laying method of the waterproof layer under the tile roof meet the requirements of a waterproof layer, the waterproof layer can be regarded as a waterproof layer. If it cannot meet the requirements of a waterproof, it can only be used as an auxiliary measure and cannot be considered as a waterproof. 2) There are hanging tiles (steel or wood hanging tiles and powder cement mortar hanging tiles) and lime-cement mortar laying tiles for the tile roof. The hanging tile method should be preferred. 3) When the tile and asphalt shingle should be used in combination with the waterproofing membrane or the coating film, the waterproofing level is Class II. 4) tile roof (including various forms of mixed


1) All roof tiles of qualified quality should be regarded as a waterproof.


When the material, thickness and laying method of the waterproof layer under the tile roof meet the requirements of a waterproof layer, the waterproof layer can be regarded as a waterproof layer. If it cannot meet the requirements of a waterproof, it can only be used as an auxiliary measure and cannot be considered as a waterproof.


2) There are hanging tiles (steel or wood hanging tiles and powder cement mortar hanging tiles) and lime-cement mortar laying tiles for the tile roof. The hanging tile method should be preferred.


3) When the tile and asphalt shingle should be used in combination with the waterproofing membrane or the coating film, the waterproofing level is Class II.


4) Block tile roofs (including various forms of concrete tiles and sintered tiles, etc.) should have measures to prevent the tiles and their underlying insulation layers, leveling layers, etc. from sliding down, such as turning up the cornice to prevent slippage, etc. measure.


5) The holes required for nails or binding tiles must be reserved on the tile. In order to prevent the tiles from falling, under normal circumstances, three rows along the cornice, one row on both sides of the ridge and one row along the gable must be nailed or tied, and lime cement mortar (1:1:6) must be used to fix the sleeping tiles. measure.


6) When the tile roof slope is greater than 50% (≈27°) and it is located in a windy area or an earthquake fortified area, all tiles need to be fixed.


7) Cast-in-place reinforced concrete, finished PVC or finished metal gutters can be used for tile roof gutters, preferably cast-in-place reinforced concrete gutters.


8) When the leveling layer of the tile roof is located above the thermal insulation layer, there should be reliable structural connection measures with the reinforced concrete base under the thermal insulation layer, such as extending the reserved steel bars on the concrete slab and the leveling layer (or the sleeping tile layer). ) within the steel (wire) mesh connection, etc.


9) When laying flat tiles in the way of mortar lying tiles, the tiles should be nailed or tied with the steel (wire) mesh in the mortar according to the provisions of Articles 5) and 6) of this section. The horizontal reinforcement spacing of the reinforcement (wire) mesh should be consistent with the spacing required for hanging tiles.


10) The leveling layer of asphalt shingles should be fine stone concrete, and its thickness should not be less than 30 mm.




Send Inquiry